EMD Millipore ICR/ICRplus Contact Plates

• Triple-bagged and gamma-irradiated contact plates ensure the highest level of safety for isolators and cleanrooms
• Maximum safety for sampling dry, sanitized surfaces in critical areas
• Suitable for air monitoring with Air Monitoring Systems
• A wide range of formulations are available to suit all needs
• These contact plates contain either Tryptic Soy Agar (TSA) or Sabouraud Dextrose Agar (SDA)
• These culture media are supplemented with neutralizers of a wide range of disinfectants or -lactam antibiotics
• Disinfectant neutralizers include: lecithin (L), tween 80 (T), histidine (H) and sodium thiosulfate (Th)
• Data matrix barcode on each plate: Paperless and secure identification of individual plates
• Transparent, H2O2-impermeable triple-sleeve packaging
• CLOSED and VENT closure options of ICRplus Contact Plates (image shown) - CLOSED position (turn the lid counter-clockwise) is recommended for aerobic incubation
• Room temperature stability
• Long shelf life
• SDA in pink plates: TSA and SDA plates easily distinguishable

Tryptic Soy Contact Agar + LT:
• Designed for the determination of the total microbial count on dry, sanitized surfaces and personnel in Isolators and Cleanrooms
• pH value: 7.3 (H2O)

Sabouraud Dextrose Contact Agar + LTHTh:
• Designed for the determination of the total viable count of yeasts and molds on dry, sanitized surfaces and personnel in Isolators and Cleanrooms
• pH value: 5.6 (H2O)

Image(s) are representative of the product group and not necessarily the individual product.
Read More
• Triple-bagged and gamma-irradiated contact plates ensure the highest level of safety for isolators and cleanrooms
• Maximum safety for sampling dry, sanitized surfaces in critical areas
• Suitable for air monitoring with Air Monitoring Systems
• A wide range of formulations are available to suit all needs
• These contact plates contain either Tryptic Soy Agar (TSA) or Sabouraud Dextrose Agar (SDA)
• These culture media are supplemented with neutralizers of a wide range of disinfectants or -lactam antibiotics
• Disinfectant neutralizers include: lecithin (L), tween 80 (T), histidine (H) and sodium thiosulfate (Th)
• Data matrix barcode on each plate: Paperless and secure identification of individual plates
• Transparent, H2O2-impermeable triple-sleeve packaging
• CLOSED and VENT closure options of ICRplus Contact Plates (image shown) - CLOSED position (turn the lid counter-clockwise) is recommended for aerobic incubation
• Room temperature stability
• Long shelf life
• SDA in pink plates: TSA and SDA plates easily distinguishable

Tryptic Soy Contact Agar + LT:
• Designed for the determination of the total microbial count on dry, sanitized surfaces and personnel in Isolators and Cleanrooms
• pH value: 7.3 (H2O)

Sabouraud Dextrose Contact Agar + LTHTh:
• Designed for the determination of the total viable count of yeasts and molds on dry, sanitized surfaces and personnel in Isolators and Cleanrooms
• pH value: 5.6 (H2O)

Image(s) are representative of the product group and not necessarily the individual product.

Certificates Of Analysis

This service is currently unavailable!

2023