3M ATTEST Rapid Readout Biological Indicators for Vaporized Hydrogen Peroxide Sterilization

Biological indicator provides results in just 24-minutes. 3M Attest Rapid Readout Biological Indicators 1295 for vaporized hydrogen peroxide (VH2O2) sterilization provide fast results. 30 each/bag. When incubated and read automatically in the 3M Attest Auto-reader 490H or the 3M Attest Auto-reader 490 having software version 4.2.7 or greater, you can document biological indicator results on the same day, during the same shift, perhaps with the same operator. Simplify your workflow and provide consistency for your staff and your patients. Use the 3M Attest Rapid Readout Biological Indicator 1295 in conjunction with the 3M Attest Auto-reader as a standard method of routine monitoring of vaporized hydrogen peroxide sterilization processes in the following systems: AMSCO V-PRO 1 Low Temperature Sterilization System (Lumen cycle), AMSCO V-PRO 1 Plus Low Temperature Sterilization System (Lumen and Non Lumen cycles), AMSCO V-PRO maX Low Temperature Sterilization System (Lumen, Non Lumen, and Flexible cycles), AMSCO V-PRO 60 Low Temperature Sterilization System (Lumen, Non Lumen and Flexible cycles) and in STERRAD 100S, STERRAD NX (Standard and Advanced cycles), STERRAD 100NX (Standard, Flex, Express and Duo cycles) systems, STERRAD NX with AllClear Technology (Standard and Advanced cycles) and STERRAD 100NX with AllClear Technology (Standard, Flex, Express and Duo cycles).

• Biological indicator provides results in just 24-minutes
• Twenty-four minute results with the 3M Attest Rapid Readout Biological Indicator System for Vaporized Hydrogen Peroxide sterilization give you the information you need when there is still time to act
• When you monitor every load, you provide the same level of care to each and every patient served by your department
• Use with the 3M Attest Auto-reader 490H or the 3M Attest Auto-reader 490 having software version 4.2.7 or greater

†Continental US+HI Only - No Exports
Read More
Biological indicator provides results in just 24-minutes. 3M Attest Rapid Readout Biological Indicators 1295 for vaporized hydrogen peroxide (VH2O2) sterilization provide fast results. 30 each/bag. When incubated and read automatically in the 3M Attest Auto-reader 490H or the 3M Attest Auto-reader 490 having software version 4.2.7 or greater, you can document biological indicator results on the same day, during the same shift, perhaps with the same operator. Simplify your workflow and provide consistency for your staff and your patients. Use the 3M Attest Rapid Readout Biological Indicator 1295 in conjunction with the 3M Attest Auto-reader as a standard method of routine monitoring of vaporized hydrogen peroxide sterilization processes in the following systems: AMSCO V-PRO 1 Low Temperature Sterilization System (Lumen cycle), AMSCO V-PRO 1 Plus Low Temperature Sterilization System (Lumen and Non Lumen cycles), AMSCO V-PRO maX Low Temperature Sterilization System (Lumen, Non Lumen, and Flexible cycles), AMSCO V-PRO 60 Low Temperature Sterilization System (Lumen, Non Lumen and Flexible cycles) and in STERRAD 100S, STERRAD NX (Standard and Advanced cycles), STERRAD 100NX (Standard, Flex, Express and Duo cycles) systems, STERRAD NX with AllClear Technology (Standard and Advanced cycles) and STERRAD 100NX with AllClear Technology (Standard, Flex, Express and Duo cycles).

• Biological indicator provides results in just 24-minutes
• Twenty-four minute results with the 3M Attest Rapid Readout Biological Indicator System for Vaporized Hydrogen Peroxide sterilization give you the information you need when there is still time to act
• When you monitor every load, you provide the same level of care to each and every patient served by your department
• Use with the 3M Attest Auto-reader 490H or the 3M Attest Auto-reader 490 having software version 4.2.7 or greater

†Continental US+HI Only - No Exports
Storage Information

59-86?F (15-30?C), 35-60% relative humidity