Traceable* Flip-Stick* Thermometers
Description
• Stainless-steel, multi-angle probe folds out for easy positioning in difficult to reach vessels
• Fully extended, chemical-resistant probe lengthens unit to 11 in. (27.9 cm)
• Unit includes MIN/MAX memory and HOLD key to freeze current display
• Flip-to-open design is easy to use. Stainless-steel probe may be positioned at any angle. Fold-up, protected probe permits carrying on the wrist strap or in a pocket
• Big-digit, 3/4-inch-high display may be viewed at a glance
• Shockproof in drop tests up to 5 feet
• Features include °F/°C switch, minimum and maximum memory readings over any time period, and a HOLD switch freezes the display to capture temperature
• Wide range covers 99 percent of routine temperature measurements: -58 to 572°F and -50 to 300°C
• Resolution is 0.1° from -20 to 200° (1° outside this range)
• Accuracy is ±1°C between -20 and 100°C
• Ultra* model accuracy is ±0.3°C at tested points
• To assure accuracy an individually serial-numbered Traceable* Certificate is provided from Control Company's ISO 17025 calibration laboratory accredited by A2LA
• It indicates traceability to standards provided by NIST (National Institute of Standards and Technology)
• Dimensions are a 0.14 inch stem diameter, 4-1/2-inch stem length, an extended length of 11 inches, 6-inch folded length, width of 5/8-inch and 1-1/2-inch-height
• Weight is 2-3/8 ounces
• Replacement battery Cat. No. 350-19942
Image(s) are representative of the product group and not necessarily the individual product.
• Fully extended, chemical-resistant probe lengthens unit to 11 in. (27.9 cm)
• Unit includes MIN/MAX memory and HOLD key to freeze current display
• Flip-to-open design is easy to use. Stainless-steel probe may be positioned at any angle. Fold-up, protected probe permits carrying on the wrist strap or in a pocket
• Big-digit, 3/4-inch-high display may be viewed at a glance
• Shockproof in drop tests up to 5 feet
• Features include °F/°C switch, minimum and maximum memory readings over any time period, and a HOLD switch freezes the display to capture temperature
• Wide range covers 99 percent of routine temperature measurements: -58 to 572°F and -50 to 300°C
• Resolution is 0.1° from -20 to 200° (1° outside this range)
• Accuracy is ±1°C between -20 and 100°C
• Ultra* model accuracy is ±0.3°C at tested points
• To assure accuracy an individually serial-numbered Traceable* Certificate is provided from Control Company's ISO 17025 calibration laboratory accredited by A2LA
• It indicates traceability to standards provided by NIST (National Institute of Standards and Technology)
• Dimensions are a 0.14 inch stem diameter, 4-1/2-inch stem length, an extended length of 11 inches, 6-inch folded length, width of 5/8-inch and 1-1/2-inch-height
• Weight is 2-3/8 ounces
• Replacement battery Cat. No. 350-19942
Image(s) are representative of the product group and not necessarily the individual product.
- Supplier/Brand
- Control Company
Loading products...
Certificates Of Analysis
This service is currently unavailable!